EQ Credit: Quality Views (1 Point)
Official FAQs
What percentage of regularly occupied space must have views?
A. 50%
B. 60%
C. 75%
D. 90%
✅ Answer: C
💡 Explanation
Under EQ Credit: Quality Views:
• At least 75% of regularly occupied floor area must have direct line of sight to the outdoors
________________________________________
⚠️ Exam Tip
👉 75% = base requirement
👉 90% = exemplary performance
B. 60%
C. 75%
D. 90%
✅ Answer: C
💡 Explanation
Under EQ Credit: Quality Views:
• At least 75% of regularly occupied floor area must have direct line of sight to the outdoors
________________________________________
⚠️ Exam Tip
👉 75% = base requirement
👉 90% = exemplary performance
At what height is view measured?
A. 30 inches
B. 36 inches
C. 42 inches
D. 48 inches
✅ Answer: C
💡 Explanation
• Views are measured from 42 inches above finished floor
👉 This represents seated eye level
________________________________________
⚠️ Exam Trap
• 30 inches = daylight workplane height
• 42 inches = views
B. 36 inches
C. 42 inches
D. 48 inches
✅ Answer: C
💡 Explanation
• Views are measured from 42 inches above finished floor
👉 This represents seated eye level
________________________________________
⚠️ Exam Trap
• 30 inches = daylight workplane height
• 42 inches = views
A project provides views for 80% of space but only meets 1 quality view type. Does it comply?
A. Yes
B. No
C. Only for schools
D. Only if atrium is included
✅ Answer: B
💡 Explanation
To comply, a project must:
1. Provide views to ≥ 75% of area ✔
2. Provide at least 2 of the 4 view quality types ❌
👉 Only meeting 1 type → NOT compliant
📌 4 View Quality Types (Know These)
1. Multiple directions (≥ 90° apart)
2. Natural elements / movement / distance
3. Unobstructed view (within 3x head height)
4. View factor ≥ 3
⚠️ Exam Tip
👉 BOTH required:
• Area threshold
• Quality criteria (≥ 2 types)
B. No
C. Only for schools
D. Only if atrium is included
✅ Answer: B
💡 Explanation
To comply, a project must:
1. Provide views to ≥ 75% of area ✔
2. Provide at least 2 of the 4 view quality types ❌
👉 Only meeting 1 type → NOT compliant
📌 4 View Quality Types (Know These)
1. Multiple directions (≥ 90° apart)
2. Natural elements / movement / distance
3. Unobstructed view (within 3x head height)
4. View factor ≥ 3
⚠️ Exam Tip
👉 BOTH required:
• Area threshold
• Quality criteria (≥ 2 types)
A project uses interior atrium views for 50% of area. What is the issue?
A. No issue
B. Exceeds 30% limit
C. Must add glazing
D. Must increase height
✅ Answer: B
💡 Explanation
• Interior atrium views can count for maximum 30% of required area
👉 50% > 30% → ❌ exceeds limit
⚠️ Exam Trap
👉 Atrium ≠ outdoor view
👉 Limited contribution only
B. Exceeds 30% limit
C. Must add glazing
D. Must increase height
✅ Answer: B
💡 Explanation
• Interior atrium views can count for maximum 30% of required area
👉 50% > 30% → ❌ exceeds limit
⚠️ Exam Trap
👉 Atrium ≠ outdoor view
👉 Limited contribution only
A project provides views in two directions but no natural elements. Which requirement is met?
A. Nature
B. Distance
C. Multiple directions
D. View factor
✅ Answer: C
💡 Explanation
• Providing views in two directions ≥ 90° apart satisfies:
👉 Multiple lines of sight requirement
________________________________________
❌ Not met:
• Nature (no natural elements)
• Distance (not stated)
• View factor (not stated)
________________________________________
⚠️ Exam Tip
👉 Each quality type is independent
👉 You only need 2 of 4 total
B. Distance
C. Multiple directions
D. View factor
✅ Answer: C
💡 Explanation
• Providing views in two directions ≥ 90° apart satisfies:
👉 Multiple lines of sight requirement
________________________________________
❌ Not met:
• Nature (no natural elements)
• Distance (not stated)
• View factor (not stated)
________________________________________
⚠️ Exam Tip
👉 Each quality type is independent
👉 You only need 2 of 4 total
A workspace has a clear window but is blocked by tall partitions. Does it qualify?
A. Yes
B. No
C. Only for offices
D. Only if 75% met
✅ Answer: B
💡 Explanation
• Views must be:
o Direct
o Unobstructed
👉 Tall partitions block line of sight → ❌ NOT compliant
________________________________________
🎯 Key Rule
👉 “Clear window” ≠ valid view
👉 Must have clear line of sight from occupant position
________________________________________
⚠️ Exam Trap
👉 Furniture and partitions count as obstructions
B. No
C. Only for offices
D. Only if 75% met
✅ Answer: B
💡 Explanation
• Views must be:
o Direct
o Unobstructed
👉 Tall partitions block line of sight → ❌ NOT compliant
________________________________________
🎯 Key Rule
👉 “Clear window” ≠ valid view
👉 Must have clear line of sight from occupant position
________________________________________
⚠️ Exam Trap
👉 Furniture and partitions count as obstructions
Comments